Single-Jet
Technology

HOW
IT WORKS
Venturi Inlet (Single Jet) - The Venturi inlet conditions
the water into a jet directing the flow and force of water towards
the tips of the impeller. This gives single jet meters the following
advantages over traditional meters:

Allows
the meter to be installed without any straight pipe in front or
behind the meter.

Takes
force off the bearing and shaft transferring the energy or force
of the water to the tips of the impeller dramatically improving
low flow accuracy and bearing wear.

Debris
passes by the impeller without jamming the meter or dramatically
wearing the impeller.

The Twin-Pivot Floating Impellar Design - The impellar
turns on a sharp tungsten carbide tip to reduce friction at low
flow, and at higher flows the impeller floats to reduce wear on
the low flow bearing.

Magnetically Driven Encoder - registers can be easily replaced
without disturbing service.

Absolute Optical Encoder - compatible with all major manufactures'
AMR solutions, the OER utilizes non-contact Light Emitting Diode
(LED) technology to provide a reading, without the friction and
wear of traditional mechanical encoders. This friction free design
not only eliminates register failures but it takes less force
to turn the impeller resulting in better low flow accuracy.
|
 |
|